Solar lighting specifications can include test results for a luminaire, an enclosure or a complete system. When you compare them, check which model and configuration were tested, which standard and edition was used, and what the result actually covers. This page explains the main tests used for solar lighting and the documentation Green Frog Systems can provide.
How to read a test result or certificate
- Model and configuration: a result applies to the model and configuration tested, not automatically to the whole range.
- Tested part: was it the luminaire, the panel, the battery enclosure or the full system on its pole?
- Standard and edition: standards are revised over time, so check the edition and year.
- Test laboratory and report date: who carried out the test and when.
- Scope of the result: what level or rating was achieved, and under what conditions.
Vibration

Street lights on poles are shaken by wind and, near roads, bridges and overpasses, by passing traffic. Solar luminaires are heavier than mains luminaires because they carry a panel and often a battery, so the mount and internal structure matter even more.
ANSI C136.31 is a luminaire vibration test widely used for roadway lighting. The luminaire’s balance point and fundamental resonant frequency are found on each of the three axes, then it is vibrated at that frequency for a set number of cycles. The standard has two levels: a normal level and a higher level for bridges and overpasses. The Aspire (December 2022) and Aeromax Pro (June 2023) luminaires passed ANSI C136.31-2018 vibration testing by TÜV Rheinland at 3 g, the higher level for bridges and overpasses. Each was vibrated for 100,000 cycles on all three axes, with no damage to the enclosure, no loosening of parts and normal operation afterwards.
Impact and vandal resistance
Impact resistance is rated using the IK code under IEC 62262, from IK01 to IK10. IK10 is the highest rating, equal to a 20 joule impact, which is roughly a 5 kg mass dropped from 400 mm. A formal IK rating applies to the specific part tested, such as the lens or the solar panel glass.
In formal testing by TÜV Rheinland in 2023, the Aeromax Pro luminaire glass and solar panel, and the Defender, achieved IK08 (a 5 joule impact) under IEC 62262.
Corrosion and salt spray
Coastal, marine and industrial sites expose lights to salt and moisture. Neutral salt spray testing under ISO 9227 exposes coated parts to a salt fog for a set number of hours, then checks for corrosion and coating breakdown.
The Defender has a third party neutral salt spray test report to ASTM B117 (2021). After 500 hours in the salt fog, the aluminium luminaire housing, solar panel and panel mounting arm showed no corrosion. The steel mounting U bolt showed surface rust from 300 hours. The Aeromax has a marine grade finish but has not been independently salt spray tested.
Ingress protection
IP ratings under IEC 60529 describe protection against dust and water. Recommended marine products have their electronics at the top of the pole with high quality IP68 rated MC4 connectors, and are designed to withstand periodic submersion. The Aspire 300 and larger models have submersible batteries.
The Aeromax Pro and the Defender have both passed IP66 testing (dust tight and protected against powerful water jets) by TÜV Rheinland in 2023.
Structural and wind loading
Poles, panels and fittings must withstand the wind loads at the site. The GFS-200, GFS-400 and Aspire ranges are designed for Wind Regions A to D under AS/NZS 1170.2, including cyclonic regions, and independent engineering certification is available for project sign off. Generic pole and foundation certification for the GFS-200 and GFS-400 is to AS/NZS 1170.2:2021.
For example, the GFS-200 lights in Karratha use a pole designed for Wind Region D by Engineering Fitness in 2017 under AS/NZS 1170.2:2011. Their foundations were certified in 2024 by a chartered engineer for Region D and Importance Level 2, at an ultimate wind speed of 80 m/s (288 km/h).
Electrical safety and market certification
Some markets require certification against specific electrical safety standards. The GFS-200, GFS-200ES, GFS-400 and GFS-400ES solar street lights are certified by TÜV Rheinland to UL 1598 (certificate CU 72192257 01) and carry the cTUVus mark, which shows compliance with UL standards recognised in the United States and Canada. The Aeromax range is certified by Intertek to ANSI/CAN/UL 8801:2022, the North American standard for photovoltaic powered luminaire systems, and has been tested for electromagnetic compatibility to FCC Part 15. The Aeromax battery and electrical box has passed UN38.3 testing for safe transport of lithium batteries by air, sea and road, and the Defender has a UKCA electromagnetic compatibility test report for the UK market. Certification for overseas markets does not by itself indicate compliance with Australian requirements.
LED performance
LED lumen maintenance is measured under IES LM-80 and projected using TM-21. It is usually reported as an L90 figure: the number of hours until the LEDs are expected to still give 90% of their original light output. Green Frog Systems luminaires use Cree XLamp XP-G3 LEDs. Cree LED’s published LM-80 results for the XP-G3 report projected L90 lifetimes of more than 100,000 hours at an 85 °C case temperature, for example L90(24k) > 145,000 hours at 700 mA. Actual life depends on drive current and operating temperature. See how long LED street lights last for what these ratings mean.
Requesting documentation
Test reports, certificates and engineering documentation are available on request for project specification and sign off. Contact our team with the product model, the project location and the documents you need.